- Data Hall Assessment: Evaluate data centers to optimize cooling efficiency by visualizing distribution of temperature, velocity, pressure, humidity, particulate contamination etc.
- ASHRAE Compliance: Ensure server rack inlet temperatures meet industry standards.
- Server Hall Layout Optimization: Enhance layout efficiency with or without cold/hot aisle containment, raised floors, false ceilings, Natural cooling, Trimmed cooling, re-circulated cooling, and more.
- Thermal Management:Address heat sources, including PDUs, RPPs, STSS, CFP, lighting, and building envelopes.
- Airflow Balancing:Optimize airflow, including the need for active tiles.
- AC Unit Efficiency:Optimize capacity and redundancy of air conditioning units like PAC, PAHU, and FWU.
- Transform your Data center Design and Operation with Digital Twin:Enabling enhanced monitoring, predictive maintenance, and efficient resource allocation by including sensor data from physical asset into virtual simulation environment.
- Integration of futuristic technologies: Evaluate advanced cooling methodologies like Liquid Cooling, Immersion cooling, phase-change material, edge racks etc for your data center.
- Real-time Data Insights: Monitor temperature and airflow dynamics in data halls over time.
- Steady State Evaluation: Determine the time required to achieve equilibrium when starting or stopping air conditioning units.
- Power Failure Scenarios: Assess utility power failures with detailed operation sequencing, including PAC unit shutdown, UPS backup, and temperature fluctuations during DG changeover.
- HVAC System Assessment: Analyze HVAC system responses, ensuring optimal performance during dynamic scenarios.
- Environmental Impact Assessment: Evaluate local ambient conditions such as wind speed, direction, temperatures, solar loading, daylight shadow, and psychrometric conditions on data center facilities.
- Exhaust Management: Ensure minimal interaction of exhaust plumes from DG radiators, flue gas, and chiller exhaust with critical equipment air intake like chillers, DGs, VRF units, cooling towers, and condenser stacks.
- Infrastructure Optimization: Optimize building orientation, layout, and surroundings for enhanced performance.
- Facility Layout Enhancements: Selection and placement of grating platforms, louvers, parapet walls, blanking panels, adiabatic cooling pads, and more.
Hydronic Computational Fluid Dynamics (CFD) Analysis is a specialized service focused on optimizing chilled water systems within data centers. It involves a detailed evaluation of the complex circuits, backup mechanisms, and temperature control systems to enhance the efficiency, reliability, and performance of data center cooling infrastructure.
- Chilled Water Systems: Analyze chilled water circuits, encompassing buffer tanks, valves, pumps, rooftop piping, chillers, and floor-level piping.
- Backup Assessment: Evaluate backup capabilities in the event of chiller failure, factoring in buffer tank volumes, UPS-backed primary and secondary pumps, and valves.
- Temperature Control: Reassess data hall temperature variations to maintain compliance with SLAs, even when the supply temperature from the buffer tank exceeds limits.
- Pressure Drop Analysis: Piping System design and pressure drop evaluation, open loop and closed loop piping system analysis.
- Equipment Sizing and design optimization: Sizing of TES tanks, Pumps, Valves, Risers etc of your piping system.
- Acoustic Simulation: We offer acoustic simulations for data center buildings, providing precise sound pressure level estimations. Ensure a quieter and more comfortable environment for your data center operations.
- Thermal Comfort Evaluation: Our experts assess thermal comfort in data center office spaces using human comfort indices such as PMV, PPD, and MAA. Prioritize the well-being of your staff with optimized environmental conditions.
- Structural Analysis: We perform Finite Element Analysis (FEA) simulations to assess the strength of critical data center components. From containment panel durability under pressure to the load-bearing capacity of server racks and tiles, we ensure structural integrity.
- Seismic Simulation: Seismic Simulation: Prepare your data center for seismic events with our seismic simulations. Safeguard your infrastructure and equipment against potential seismic impacts.
- Critical Electronic Components Thermal Management: Cooling analysis of individual Servers, including PCBs, Board mounted electronics, fans, heat sinks etc.
- EMI/EMC Simulation: Our EMI/EMC simulations evaluate the electromagnetic interference and compatibility of data center electronics components. Ensure the reliability and performance of your critical IT equipment.
With our comprehensive range of analysis services, we empower you to optimise data centre efficiency, safety, and performance, ensuring a resilient and reliable environment for your mission-critical operations.